System: UPES Emergency Communication System (UPES-ECS) Type: LAN-only campus emergency + internal SIP calling on Asterisk (FreePBX) Primary user device: Mobile phone on campus Wi-Fi + SIP app Identity model: SAP ID = SIP extension = SIP username Build: FreePBX (web admin) on top of Asterisk, one local server upes-ecs-pbx-01

Students only ever need to remember one thing: Dial 111.


What is in this folder

Plan & build

# Document Audience Purpose
29 Day-1 Quickstart IT / builders Shortest path: bare server → working "Dial 111".
07 Master Implementation Plan Everyone The phased roadmap (Phase 0 → later). Start here.
08 FreePBX Build Guide IT / Admin Hands-on Phase 0 + Phase 1 server steps.
09 Dialplan Design IT / Admin Reference dialplan for the custom emergency logic.
15 Local Infrastructure Diagram IT Network layout, server, segmentation, quality targets.

Operate

# Document Audience Purpose
01 Numbering Plan IT / ERT / Admin The master number map. Everything references this.
02 ERT SOP ERT Operators & Lead How to answer 111, classify, dispatch, log, close.
03 Drill & Test SOP ERT Lead / IT How to test the system safely without causing panic.
04 SIP Account & Role Matrix IT / Admin Who can do what. The access-control source of truth.
30 Responder Roles & Shifts ERT Lead / IT Generic positions (ERT + Medical/Security/…) staffed by shift, not named people.
31 Training Plan All roles Train every role before go-live; refreshers + reserves for surge.
10 Health Monitoring Checklist IT / ERT Lead Is the system actually ready right now?
12 Incident Logging Schema IT / ERT Structured record for every emergency call.
13 Recording & Retention Policy Admin / IT What's recorded, for how long, who can access.
14 Device Provisioning Sheet IT / Admin Create / assign / revoke SIP accounts + devices.

Users

# Document Audience Purpose
05 Student SIP Setup Guide Students / Staff Install app, log in with SAP ID, dial 111.
06 ERT SIP Setup Guide ERT / Fixed devices ERT phone + desk device setup and answering.

Roll out & prove

# Document Audience Purpose
16 Rollout Plan All Staged deployment (lab → ERT → devices → users → paging).
17 Pilot Test Plan IT / ERT Lead The 19-test matrix that must pass.
32 Test Evidence & Sign-off Sheet IT / ERT Lead / University Fill-in record proving each pilot test passed; go-live evidence.
11 Backup & Restore Procedure IT / Admin Local-first backups + tested restore.
18 Go-Live Checklist Approvers Final gate + sign-off before production.

Later phases

# Document Audience Purpose
19 AI Assistant Line 101 IT / ERT Lead Local-first AI triage (no cloud) that always falls back to 111.
20 Multi-Campus Wireless IT Bidholi ↔ Kandoli rooftop wireless bridge.
23 Mobile Van & Repeater Deployment IT / ERT Lead Self-powered PBX-in-a-van + corner repeaters for disaster mode.
24 Mobile App Reliability & Battery Users / IT Keep the SIP app registered so callbacks work.

Harden & own

# Document Audience Purpose
26 Security Hardening & Abuse IT SIP hardening, firewall, prank/DoS handling.
27 Ownership & RACI IT / ERT Lead / University Who owns what; no single point of failure.

Review & reference

# Document Audience Purpose
21 Risk Register & Known Gaps IT / ERT Lead / University Honest list of what can fail + fixes. Read before go-live.
22 Glossary Everyone Plain-language key to terms, acronyms, and numbers.
25 Quick-Reference Cards ERT / Van / Students Print-and-post one-pagers + "Dial 111" poster.
28 Voice Prompt Scripts Whoever records audio Exact wording for every recorded prompt.

Config, scripts & provisioning (outside this folder)

Path Purpose
../config/ extensions_custom.conf + install/wiring README
../scripts/ Helper scripts: incident ID, missed-incident, health check, retention, logging
../provisioning/ CSVs: pilot-users (people), responder-positions (shift roles), fixed-devices

Golden rules (apply to every document)

  1. 111 is human-first and must never depend on AI, internet, or cellular. When no human answers, the offline panic-coach (102) picks up automatically.
  2. If anyone is ever unsure → escalate. Never drop an emergency call silently.
  3. Only 111 / 199 (drill) flows are recorded. Student-to-student calls are never recorded.
  4. Emergency control features (paging, conference, recordings) are role-restricted.
  5. Every change to the live server takes a backup first.

Numbering at a glance

111    Emergency Hotline (human-first ERT) — the number to dial
100    DEPRECATED / removed (old Police-association alias; no longer dialable)
102    Offline panic-coach — deterministic first-aid, zero internet; auto fallback when no human answers (also dial to test)
101    Local-first AI triage assistant (later phase; never dialed by a caller)
199    Drill / Test line (safe, no real dispatch)
198    Echo / audio test (optional)
196    Internal AI test line (later)

700-799   Emergency paging zones
9000-9099 Incident command conference rooms
4000-4999 Fixed campus devices (desk phones, IP speakers)
*22 / *23 Responder go on / off shift (join / leave emergency queue)
*45 / *46 ERT queue Pause / Resume

<SAP ID>  Every human user's extension

Status of decisions

All naming, numbers, timeouts, and role rules in these documents come from the UPES-ECS Filled Decision Questionnaire. Items marked TBD must be collected from UPES IT before go-live (server IP, Wi-Fi SSID, client-isolation status, final ERT roster, final fixed-phone locations, university recording-retention policy).